Toll Free: 800-682-6528   |   Local Phone: 252-291-7808   |   Fax:  252-291-1324   |   Email:  info@aircompeq.com

CAREERS          SITE MAP          HOME

Air Dryers - Ultra Air - Control Panel & Accessories

Standard Control Panel for UA100 - UA2000

Standard Control Panel for Ultra Air UA100 - UA2000 Air Dryers

 
  • Dryer ON/OFF Switch and Light
  • Power ON Light
  • Drain ON Light
  • Drain OFF Time Controller
  • Drain ON Time Controller
  • Refrigerant Suction Gauge - Pressure
  • Drain PUSH TO TEST button
  • Refrigerant Discharge Gauge - Pressure
 

Electronic Control Panel and Monitoring System (optional UA100-UA2000)

Electronic Control Panel and Monitoring System for Ultra Air Air Dryers (Optional UA100-UA2000)

The solid state construction includes a microprocessor and digital readout to control and monitor the following functions:
 

Monitors:

  • Evaporator Temp
  • Ambient Air Temp
  • Inlet Air Temp
  • Drain On Light
  • Power On

Controls:

  • Compressor
  • ON Switch
  • Drain Open Time
  • Drain Closed Time

Selecting the Proper Dryer

Air dryer rated capacities are based on 100°F inlet temperature, 100 PSIG inlet pressure and 100°F ambient temperature. Actual capacities will vary based on actual operating conditions. For different conditions use dryer correction factor matrix.

 

Dryer Correction Factors

Inlet Temperature 80 90 100 110 120 130
Correction Factor 1.30 1.15 1.0 0.83 0.7 0.6
Inlet Pressure (PSIG) 40 50 60 70 80 90
Correction Factor 0.76 0.80 0.84 0.88 0.92 0.96
Inlet Pressure (PSIG) 100 110 120 130 140 150
Correction Factor 1.0 1.02 1.04 1.06 1.08 1.10
Ambient Air Temperature 80 90 100 110    
Correction Factor 1.10 1.05 1.0 0.90  
 

Examples:

To calculate the capacity of model UA300 at 90°F inlet temperature, 120 psig inlet pressure and 100° F ambient temperature.

 

Dryer
Capacity

SCFM
300

Inlet
Air Temp
C/F

x 1.15

Inlet
Pressure
C/F

x 1.04

Ambient
Temp.
C/F

x 1.0

=

Actual
SCFM
Capacity

358.8

 

Accessories

Ultra Air High Capacity Dryers 2500-15000 SCFM

Coalescer, Particulate and Coalescer Filters

UA - High Capacity Dryers
2500-15000 SCFM

Coalescer, Particulate and
Coalescer Filters

 

Deliquescent Dryers

After Coolers

Deliquescent Dryers

After Coolers

   

LFT Heatless Regenerative Air Dryers 25-5000 SCFM

LFE Externally Heated Regenerative Air Dryers 25-5000 SCFM

Heatless Regenerative Air Dryers
25-5000 SCFM

LFE
Externally Heated Regenerative Air Dryers
25-5000 SCFM

   

LFA Externaly Heating/Blower Purge Regenerative Air Dryers 100-5000 SCFM

Drains

LFA
Externally Heating/Blower Purge
Regenerative Air Dryers
100-5000 SCFM

Drains

 
 

Click to view Air Dryers

 

Air Compressor Equipment Inc.
P.O. Box 3961, 1901 Baldree Road, Wilson, NC  27895
Toll Free: 800-682-6528  /  Phone: 252-291-7808  /  Fax: 252-291-1324  /  Email:  info@aircompeq.com

 