Standard
Control Panel for UA100 - UA2000 |
|
 |
| |
-
Dryer ON/OFF Switch and Light
-
Power ON Light
-
Drain ON Light
-
Drain OFF Time Controller
-
Drain ON Time Controller
-
Refrigerant Suction Gauge - Pressure
-
Drain PUSH TO TEST button
-
Refrigerant Discharge Gauge - Pressure
|
| |
Electronic Control Panel
and Monitoring System (optional
UA100-UA2000) |
|
 |
|
The solid state construction includes a
microprocessor and digital readout to
control and monitor the following functions: |
| |
Monitors:
-
Evaporator Temp
-
Ambient Air Temp
-
Inlet Air Temp
-
Drain On Light
-
Power On
|
Controls:
-
Compressor
-
ON Switch
-
Drain Open Time
-
Drain Closed Time
|
Selecting the Proper
Dryer
Air dryer rated capacities are based on
100°F inlet temperature, 100 PSIG inlet
pressure and 100°F ambient temperature.
Actual capacities will vary based on actual
operating conditions. For different
conditions use dryer correction factor
matrix. |
| |
Dryer Correction Factors
|
|
Inlet Temperature |
80 |
90 |
100 |
110 |
120 |
130 |
|
Correction Factor |
1.30 |
1.15 |
1.0 |
0.83 |
0.7 |
0.6 |
|
Inlet Pressure (PSIG) |
40 |
50 |
60 |
70 |
80 |
90 |
|
Correction Factor |
0.76 |
0.80 |
0.84 |
0.88 |
0.92 |
0.96 |
|
Inlet Pressure (PSIG) |
100 |
110 |
120 |
130 |
140 |
150 |
|
Correction Factor |
1.0 |
1.02 |
1.04 |
1.06 |
1.08 |
1.10 |
|
Ambient Air Temperature |
80 |
90 |
100 |
110 |
|
|
|
Correction Factor |
1.10 |
1.05 |
1.0 |
0.90 |
|
|
| |
Examples:
To calculate the capacity of model UA300 at
90°F inlet temperature, 120 psig inlet
pressure and 100° F ambient temperature. |
| |
|
Dryer
Capacity |
SCFM
300 |
Inlet
Air Temp
C/F
x 1.15 |
Inlet
Pressure
C/F
x 1.04 |
Ambient
Temp.
C/F
x 1.0 |
= |
Actual
SCFM
Capacity
358.8 |
|
| |
Accessories |
|
 |
 |
|
UA - High Capacity Dryers
2500-15000 SCFM |
Coalescer, Particulate and
Coalescer Filters |
| |
|
 |
 |
|
Deliquescent Dryers |
After Coolers |
| |
|
|
 |
 |
|
Heatless Regenerative Air Dryers
25-5000 SCFM |
LFE
Externally Heated Regenerative Air Dryers
25-5000 SCFM |
| |
|
|
 |
 |
|
LFA
Externally Heating/Blower Purge
Regenerative Air Dryers
100-5000 SCFM |
Drains |
| |
| |
|
|