									Zander Variable Speed 
									Refrigerated Air Dryer 
									ZVSD Series - 300 to 2800 scfm | 
								
								
									| 
									 
												
												
												   | 
									
									
									Zander's ZVSD dryers match the energy 
									consumed to the actual compressed air usage. 
									The ZVSD precisely controls the outlet 
									pressure dew point by monitoring the 
									refrigeration suction pressure.  
									 
									This single task accomplishes two critical 
									goals. First, by varying the speed of the 
									refrigeration compressor to match inlet 
									conditions, we lower dryer electrical 
									consumption at reduced loads. Second, the 
									pressure dew point exiting the air dryer has 
									virtually no change throughout the entire 
									range of flow. 
									 
									Click photo for larger view. | 
								
								
									|   | 
									  | 
								
								
									The Results: | 
									The Benefits: | 
								
								
									
									
										- 
										
										Substantial energy savings
 
										- 
										
										Substantial dollar savings
 
										- 
										
										Stable outlet dew point
 
									 
									 | 
									
									
										- 
										
										Unparalleled Standard Features
 
										- 
										
										Performance Guarantee
 
										- 
										
										Lowest Energy Cost
 
										- 
										
										Compressor & Heat Exchanger Five Year 
										Warranty Available
 
										- 
										
										Proven Lab Performance
 
									 
									 | 
								
								
									|   | 
								
								
									ZVSD vs Cycling Dryers
									 | 
								
								
									| 
									
									The Zander ZVSD perfectly matches input kW 
									with the heat load on the refrigerated 
									dryer. The result is our ability to save 
									energy dollars like never before. You will 
									witness the energy savings immediately upon 
									ZVSD start up. Input kW is registered on the 
									front of Micro-Con (hand held Micro-Por 
									variable drive programmer). | 
								
								
									|   | 
								
								
									| 
									 
										   | 
								
								
									|   | 
								
								
									| 
									
									Competitive cycling dryers depend upon an 
									inefficient "third" heat exchange within the 
									evaporator to cycle the dryer OFF and ON. 
									Several competitive cycling dryers tested 
									registered outlet dew points above 60®F 
									before the compressor restarted. | 
								
								
									|   | 
								
								
									| 
									 
										   | 
								
								
									|   | 
								
								
									STANDARD FEATURES
									 | 
								
								
									ZVSD Integrated Circut 
									Control System | 
								
								
									| 
									How has Zander been able to simplify the 
										refrigerated air dryer but add 
										unheard-of features and benefits, all 
										standard? The secret is in the 
										intelligence we've designed into the 
										world's most advanced dryer. | 
								
								
									|   | 
								
								
									
									
										- 
										
										Therma-Save Protection
 
										- 
										
										Therma-Save Plus
 
										- 
										
										Zero-Air Loss Drain
 
										- 
										
										Cycle-Saver OFF at 10 psi/ON at 40 psi
 
										- 
										
										True Dew Point Indicator
 
										- 
										
										Fan Cycling Controls
 
										- 
										
										Ambient Air Filter
 
									 
									
									
									Check out the models below and then contact 
									us for more information, literature and 
									prices.  | 
								
								
									|   | 
								
								
									
									
										
										
											
												| 
												
												Model | 
												
												
												SCFM 
												Capacity 
												33-39®F pdp | 
												
												
												Pressure 
												Drop 
												psid | 
												
												
												Fan 
												CFM | 
												
												
												Heat Load 
												Rejection 
												Btu/Hr | 
												
												
												Voltages 
												230/ 460/ 575/  
												3/60 3/60 3/60  | 
												
												
												Nominal 
												Ref. Hp | 
												
												
												In/Out 
												Connect 
												Size | 
												
												
												Weight 
												lbs. | 
											 
											
												| 
												
												ZVSD300 | 
												
												
												300 | 
												
												1.2 | 
												
												1556 | 
												
												
												21000 | 
												
												
												OPT   STD   OPT | 
												
												1.5 | 
												
												1 
												1/2" | 
												
												440 | 
											 
											
												| 
												
												ZVSD400 | 
												
												
												400 | 
												
												2.2 | 
												
												1867 | 
												
												
												26000 | 
												
												
												OPT   STD   OPT | 
												
												2.0 | 
												
												2" | 
												
												460 | 
											 
											
												| 
												
												ZVSD500 | 
												
												500 | 
												
												1.6 | 
												
												1867 | 
												
												
												32000 | 
												
												
												OPT   STD   OPT | 
												
												2.5 | 
												
												2" | 
												
												480 | 
											 
											
												| 
												
												ZVSD650 | 
												
												650 | 
												
												2.8 | 
												
												3558 | 
												
												
												40000 | 
												
												
												OPT   STD   OPT | 
												
												3.0 | 
												
												2" | 
												
												500 | 
											 
											
												| 
												
												ZVSD800 | 
												
												800 | 
												
												1.6 | 
												
												3558 | 
												
												
												48000 | 
												
												
												OPT   STD   OPT | 
												
												4.0 | 
												
												3" | 
												
												600 | 
											 
											
												| 
												
												ZVSD1000 | 
												
												1000 | 
												
												2.5 | 
												
												3558 | 
												
												
												60000 | 
												
												
												OPT   STD   OPT | 
												
												5.0 | 
												
												3" | 
												
												620 | 
											 
											
												| 
												
												ZVSD1250 | 
												
												1250 | 
												
												2.2 | 
												
												7000 | 
												
												
												74000 | 
												
												
												OPT   STD   OPT | 
												
												5.0 | 
												
												3 
												flg | 
												
												940 | 
											 
											
												| 
												
												ZVSD1500 | 
												
												1500 | 
												
												2.8 | 
												
												7000 | 
												
												
												87000 | 
												
												
												OPT   STD   OPT | 
												
												7.5 | 
												
												3 
												flg | 
												
												950 | 
											 
											
												| 
												
												ZVSD1750 | 
												
												1750 | 
												
												2.1 | 
												
												7000 | 
												
												
												101000 | 
												
												
												OPT   STD   OPT | 
												
												10.0 | 
												
												4flg | 
												
												1050 | 
											 
											
												| 
												
												ZVSD2000 | 
												
												2000 | 
												
												2.6 | 
												
												7000 | 
												
												
												115000 | 
												
												
												OPT   STD   OPT | 
												
												12.0 | 
												
												4flg | 
												
												1190 | 
											 
											
												| 
												
												ZVSD2300 | 
												
												2300 | 
												
												2.4 | 
												
												7000 | 
												
												
												132000 | 
												
												
												OPT   STD   OPT | 
												
												12.0 | 
												
												6flg | 
												
												1490 | 
											 
											
												| 
												
												ZVSD2800 | 
												
												2800 | 
												
												3.0 | 
												
												7000 | 
												
												
												148000 | 
												
												
												OPT   STD   OPT | 
												
												15.0 | 
												
												4flg | 
												
												1620 | 
											 
										 
										 |